-5%

Drive MQ3200 Deluxe Pulse Oximeter With Alarms Plethysmogram

Drive DeVilbiss Healthcare

$118.50 $124.74

This is the all new MedQuip MQ3200 pulse oximeter by Drive. The Medquip MQ3200 is a high value, feature rich monitor for measuring SPO2 oxygen saturation and heart rate.

It is designed for spot-check oxygen saturation of aterial hemoglobin (SPO2) and pulse rate. It is intended for occupational, clinical use by trained professionals.

Free carrying case included.

 

THIS NEWLY DESIGNED UNIT HAS A HEART RATE GRAPH AND USER SPECIFIED PULSE AND SPO2 AUDIBLE ALARMS.

 

Highly Accurate :

Although very cost effective, the monitor provides a SPO2 accuracy of +/- 3% in a range of 70-100%. The heart rate measurment accuracy is =/1 2 beats per minute within a range of 30-99 bpm and +/- 2% within a pulse range of 100 – 235 bpm.

Low Maintenance :

Requires no routine calibration or maintenance other than replacement of batteries. Batteries provide approximately 30 hours of continuous operation (approximately 3,000 measurements).

 

Limitations :

This finger pulse oximeter will NOT monitor SPO2 during activity and movement. You must stop the current activity and take the reading while stationary.

Movement will cause readings to be affected by artifact. Also, this unit is not designed for continuous monitoring.

 

SPECIFICATIONS
  • Display mode: OLED
  • SPO2 Measurement range: 70-100% (note normal range is above 93%)
  • Measurement Accuracy: +-2%
  • Pulse Rate Measuring range: 30-250 bpm
  • BPM Accuracy: +-2 BPM
  • Data Update time: < 15s
  • Pulse Intensity: Bar graph Indication
  • Power Requirements: Two AAA alkaline Batteries

    Pulse Wave Display: columniation display and the waveform display

  • Battery consumption: Two AAA 1.5V, 600mAh alkaline batteries can be continuously used as long as 30 hours
  • Dimension: Length: 61mm (2.40″�) Width: 36mm (1.41″�) Height: 32mm (1.25″�)
  • Weight: 57g (2.01 ounces) – including two AAA batteries
  • Operating Temp: 5 – 40 Centigrade Storage Temp: -20 – 70 Centigrade
  • Operating Humidity: 15% – 80% RH
  • Storage Humidity: < 95% RH

    Resolution: 1% for SpO2 and 1 bpm for Pulse Rate.

    Power Consumption: Smaller than 30mA.

    Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural and that of a dark room is less than +-1%. It is equipped with a function switch. The oximeter can be powered off in case no finger is the Oximeter within 5 seconds.

    Optical Sensor:
    Red light (wavelength is 660nm, 6.65mW)
    Infrared (wavelength is 880nm, 6.75mW)